02Case study · 2024
Office LED retrofit
Swapped 650 fluorescent troffers for low-glare LED panels with DALI dimming and daylight sensors across a 22,000 sq ft floor plate.
Commercial Tampines, Singapore 3 weeks (after-hours)

Sector
Commercial
Fixtures
650
Energy cut
52%
Area
22k ft²
The brief
What the client needed.
Office stayed fully occupied during the day. Existing wiring lacked a dimming bus, and the suspended ceiling tiles were fragile.
Our approach
How we delivered it.
We worked 8pm–5am for 15 nights, pulled a fresh DALI bus zone-by-zone, and reused existing tile cut-outs to avoid ceiling damage. Daylight sensors were tuned per facade orientation.
Outcome
The result on hand-over.
Measured 52% lighting energy reduction in the first month. Tenant received rebate documentation for green-mark recertification.
Scope delivered
What we installed.
- 650 × 600mm LED panels (UGR<19)
- DALI-2 controller & wiring
- Daylight + occupancy sensors
- Commissioning & scene programming
- 5-year product warranty
Have a similar scope?